BELZONA® PROTECTS FRACTIONATOR TOWER

KHIA ID: 359
Industry: Oil & Gas (OILG)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Steel
Customer Location: Refinery in Singapore
Application Date: April 2001
Products:

Belzona® 5851 (HA-Barrier)


Problem: CUI (Corrosion Under Insulation) particularly around the support rings where moisture had accumulated.
Photograph Descriptions

General view of the tower. The degree of corrosion clearly evident on the support rings. Application underway. Application complete.

Application Situation
Fractionator tower in cracker unit.
Application Method
The application was carried out in accordance with Belzona Know-How System Leaflet TCC-5.The insulation was removed from affected areas, substrate prepared and Belzona® 5851 (HA-Barrier) applied to the hot substrate.
Belzona Facts
Belzona® 5851 provides excellent corrosion protection to these badly cor-roded areas without interruption to production.