BELZONA REBUILDS FLANGE FACE ON FILTER

KHIA ID: 1346
Industrie: Power (POWR)
Anwendung: VPF-Valves, Pipes and Fittings (VPF)
Substrat: Steel
Standort des Kunden: Hydroelectric Power Plant, Russia
Antragsdatum: December 2007
Produkte:

Belzona® 2111 (D&A Hi-Build Elastomer)


Problem: Rubber had been damaged due to long years in service and was badly deteoriated. Sealing  of the flange lost. Rubber in seal area had lost adhesion to the substrate.
Fotobeschreibungen
  1. Deteoriated flange face before the application
  2. Surface preparation to flange face
  3. Completed application

 

Anwendungssituation
Rubber covered flange in the filter.
Anwendungsverfahren
Application was carried out in accordance with Belzona Know-How System Leaflet VPF-13. A plastic former was manufactured and coated with Belzona® 9411 (Release Agent) before being used to form the Belzona® 2111 to precise contours.
Belzona-Fakten
Belzona saved the customer time and money, application finished with minimum shutdown.