Belzona® Repairs Roof Leak

 
 

Industry:

Buildings & Structures (BSTR)

 
 

Application:

Roof Problem Areas (RPA)

 
 

Customer Location:

Washington, USA

 
 

Application Date:

1984

 
 

Application Situation:

Metal roof flashing.

 
 

Problem:

Continual ice build up in the valley forced water under the roof panels due to poor roof design, causing leaks. Someone decided to remove the ice with an ax, causing holes and more leaks.

 
 

Products:

Belzona 3111 (Flexible Membrane)

Belzona 3921 (GSC Surface Conditioner)

Belzona 9311 (Reinforcing Sheet)

 

 

Substrate:

Steel

 
 

Application Method:

The flashing was properly cleaned and abraded. Belzona 3921 was brushed on followed by two coats of Belzona 3111 being applied with Belzona 9311, which was laid onto the substrate. The application was carried out in accordance with Belzona Know-How System Leaflet RPA-8.

 
 

Belzona Facts:

Replacing the flashing would have required the removal of most of the roof panels, a considerable expense. The customer was very satisfied with Belzona's solution.

 
 

Photographs Description

  1. Valley flashing showing ax holes
  2. Brushing on Belzona 3921
  3. First coat of Belzona 3111 with reinforcing sheet
  4. Completed application
 
Case study pic one

 

 