KHIA ID: 357Industry: Water / Wastewater (WATR)
Application: PDP-Positive Displacement Pumps (PDP)
Substrate: Rubber and steelCustomer Location: Water treatment plant.
Application Date: 1987Products:Belzona ® 2131 (D&A Fluid Elastomer)
Belzona ® 2911 (QD Conditioner)
Problem: The two intermeshing rubber lobes in the pump rapidly wear and the clearances increase reducing the pumps efficiency. Replacement of the lobes is necessary but expensive and long lead times exist for repalace-ment lobes from the manufacturer.