BELZONA ELIMINATES TRIP HAZARD FROM DRAIN COVERS

KHIA ID: 6185
Industry: Buildings & Structures (BSTR)
Application: FPA-Floor Problem Areas (FPA)
Substrate: Concrete
Customer Location: Shopping centre, Bankstown, Australia
Application Date: May 2004
Products:

Belzona 4111 (Magma Quartz)

Belzona 4411 (Granogrip)


Problem: Existing drain covers were proud of surface creating a potential trip hazard.
Photograph Descriptions

1. The raised drain plate

 

2. Belzona 4111 to rebuild drain

 

3. The plate fixed in place

 

4. Coated with Belzona 4411

Application Situation
Drain covers in various areas of shopping centre. 
Application Method
Application was carried out in accordance with Belzona Know- How System leaflets FPA-1 & FPA-8. Concrete was ground away and Belzona 4111 used to re-install plates at ground level. Plates were then coated with Belzona 4411 Granogrip to provide slip resistance.
Belzona Facts
The finished outcome eliminated the trip hazard and installation did not impact on normal operations around the shopping centre.