BELZONA PROTECTS CO2 ABSORBER TOWER
Industry: Chemical & Petrochemical (PETR)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Carbon Steel
Customer Location: Fertilizer plant, Bulgaria
Application Date: August, 2014
Products:
Belzona® 1311(Ceramic R-Metal)
Belzona® 1391(Ceramic HT-Metal)
Problem: Vessel was working without lining and suffering severe internal corrosion due to presence of amines MEA/MDEA at elevated temeperature up to 100ºС. Coating required to extend service life of the vessel.
Photograph Descriptions
1. General view of the tower 2. Severe pitting was revealed after surface preparation by abrasive blasting 3. Application of the first coat of Belzona 1391 underway 4.View of the final application. Belzona 1391 was applied in two coats with grit blasting between the first and the second coat
Application Situation
CO2 Absorption tower 41m high, 4m diameter - lower part
Application Method
Application was carried out in accordance with Belzona Know-How Leaflets TCC-3 & TCC-5. Belzona® 1311 was used to repair pitting and to smooth out weld repairs before the lower part of the vessel was coated with Belzona® 1391.
Belzona Facts
Previously the eroded/corroded areas had been repaired by the customer's own staff welding and grinding those areas almost each year during seasonal shutdowns for maintenance. This sort of conventional repair presented a safety risk and was time consuming. The decision to use cost-effective Belzona protective system saved company money, time and reduced risk. In addition Belzona coating will provide long term resistance to the chemical attack and corrosion.