BELZONA PROTECTS NEW GLYCOL TANK

KHIA ID: 6146
Industry: General Industry (GIND)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Mild steel
Customer Location: Steel fabrication company, Scotland, UK
Application Date: June 2016
Products:

Belzona 5811 (Immersion Grade)


Problem: The tank is to contain Propylene Glycol so it was expected that in service corrosion would be experienced. A short turn around time was required for this tank to be returned to service within the customers expectations. Access was also restricted within the tank due to the internal furniture.
Photograph Descriptions

1. Newly fabricated tank

2. Tank onsite, laid on its side

3. Coating underway

4. Completed application

Application Situation
A newly fabricated tank for an industrial refrigeration system was in need of corrosion protection.
Application Method
Application was carried out in accordance with Belzona system Leaflet TCC-5.
Belzona Facts
The choice was between a corrosion resistant coating & fabricating a new tank out of stainless steel. Cost & lead time favored the coating option.