BELZONA PROVIDES SAVINGS BY SEALING FLOOR

KHIA ID: 5349
Industry: Buildings & Structures (BSTR)
Application: FPA-Floor Problem Areas (FPA)
Substrate: Urethane
Customer Location: WA, USA
Application Date: 1992
Products:

Belzona 2221 (MP Fluid Elastomer)

Belzona 2911 (Elastomer QD Conditioner)

Belzona 9341 (Reinforcing Sheet)


Problem: The seams on the floor in the large animal surgery room had split open, allowing bacteria to flourish underneath. The floor had to be sealed.
Photograph Descriptions
  1. Drying the floor after cleaning
  2. Abrading the surface
  3. Applying Belzona 2221 over the seams
  4. Completed application
Application Situation
Large animal surgery room.
Application Method
The floor was cleaned and disinfected, and then allowed to dry. A roughing tool was used to abrade the surface. Belzona 2911 was applied and allowed to cure. The area was masked off and Belzona 2221 was brushed on with Belzona 9341 to bridge the seam. The application was carried out in accordance with a modified version of Belzona Know-How System Leaflet FPA-6.
Belzona Facts
Belzona solved the problem in a very cost-effective manner. The only alternative solution was a complete replacement of the flooring, which was deemed too expensive.