BELZONA PROVIDES THE SOLUTION TO A PUMP PROBLEM
Industry: Water / Wastewater (WATR)
Application: CEP-Centrifugal Pumps (CEP)
Substrate: Cast Iron
Customer Location: Lake Stevens, WA, USA
Application Date: May 2016
Products:
Belzona 1111 (Super Metal)
Belzona 1321 (Ceramic S-Metal)
Problem: The pump had a 1/4" hole appear on the outside of the volute, allowing for wastewater to leak during operation. After opening the pump, it was discovered that there was fairly extensive damage in four locations as well as damage to the cutwater and erosion in the throat and on the flange face.
Photograph Descriptions
- Top: Hole in the volute / Bottom: Damage to cutwater.
- Top: Hole in volute repaired / Bottom: Damage to cutwater repaired with 1111.
- Flange face damage / Flange face damage repaired.
- Completed application with 1321 overcoat.
Application Situation
Wastewater pump.
Application Method
The customer purchased a grit blasting cabinet for this project to ensure proper surface preparation. After grit blasting, more surface damage was discovered in the throat of the pump and the flange face. Belzona 1111 was used to fill in the damage, patch the hole and smooth over the pitted surface and damaged flange face. As soon as Belzona 1111 was firm, Belzona 1321 was applied in the usual 2-coat/2-color system as recommended. The application was done with a modified version of CEP-6.
Belzona Facts
The repairs on this used 3 cubic inches of Belzona 1111 and 1 kg total of Belzona 1321, making the actual product used cost less than $350.00 USD. With a replacement in the $4000.00 USD range, this was an easy way to save revenue and extend the life of their assets.