BELZONA REPAIRS AND IMPROVES FRANCIS TURBINE RUNNER

KHIA ID: 707
Industry: Power (POWR)
Application: CEP-Centrifugal Pumps (CEP)
Substrate: Steel
Customer Location: Hydroelectic Power Plant, Czech Republic
Application Date: September 2003
Products:

Belzona® 1111 (Super Metal) Belzona® 1341 (Supermetalglide)


Problem: The runner had suffered extensive damage from erosion, corrosion and mechanical damage.
Photograph Descriptions

Damaged and worn runner After grit blasting Rebuilding with Belzona® 1111 After coating with Belzona® 1341

Application Situation
Francis Turbine Runner
Application Method
The application was carried out in accordance with Belzona® Know-How System Leaflets CEP-8 and CEP-10.
Belzona Facts
 After the repair and coating of both the runner and wicket gates a 10 - 15% increase in output was recorded and the turbines were able to run at a greater range of heads than were possible before, thus earning the customer many time more in profit than the cost of the repair. After one year operation the runner was inspected and was found to have only suffered minor damage due to impact with pieces of wood. A further inspection in 2006 showed runner still to be in excellent condtion and in 2010 client expressed himself happy with the application.