BELZONA REPAIRS AND PROTECTS MACHINE TOOL COOLANT TANK

KHIA ID: 884
Industry: General Industry (GIND)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Mild Steel
Customer Location: Aerospace Component Manufacturer, KS
Application Date: February 2007
Products:

Belzona® 1111 (Super Metal)

Belzona® 5811 (Immersion Grade)


Problem: The cutting fluid is water based. The tanks rust because the cutting fluid and the cuttings sit on the bottom of the tank. The tanks leak and cause a big mess and safety hazard.
Photograph Descriptions
  1. Typical rust holes 
  2. Blast cleaned tank 
  3. Totally sealed tank
Application Situation
Coolant tanks containing cutting fluid.
Application Method
Application was carried out in accordance with Belzona Know-How System Leaflet TCC-5.
Belzona Facts
Successful long term results provide the machinist with a safe worry free work environment.