Customer Location: Austrian paper mill
Application Date: April 1992
Products:

Belzona® 1111 (Super Metal)


Problem: Operator error in cross threading the inlet fittings in the casing of two steel venturi eductor nozzles damaged the units and were unable to func-tion properly.
Photograph Descriptions
  1. View of damaged venturi casing
  2. View of eductor nozzles during forming process
  3. Completely reformed threads
Application Situation
Steel venturi eductor nozzles.
Application Method
The application was carried out in accordance with Belzona Know-How System Leaflet ENC-2.
Belzona Facts
Belzona® 9411 (Release Agent) was applied to the male threaded fitting and allowed to dry for at least 20 minutes. Belzona® 1111 (Super Metal) was then applied to the threads of both the male and female components and brought together immediately. Following full cure, the fittings were removed to reveal perfectly reformed threads without machining.