BELZONA SEALS AIR COOLER COVER
Industry: Marine (MRNE)
Application: HEX-Heat Exchangers (HEX)
Substrate: Steel
Customer Location: Ship Repair Workshop, Turkey
Application Date: September, 2020
Products:
Belzona 2911 (QD Conditioner)
Belzona 2211 (MP Hi-Build Elastomer)
Problem: Due to the design of the Air Cooler, the gasket under the cover could not be changed. Over time and vibrations of Cooler, the deformed gasket lost its sealing and caused the performance of Air Cooler to decrease.
Photograph Descriptions
1. Leaking Area
2. Defining the application Area
3. Filling between cover and case with Belzona 2211.
4. After the application finished.
Application Situation
Air Cooler Cover Connection Line
Application Method
The application was carried out in accordance with Belzona Know-How System Leaflet HEX-13b. Application area preparation has done as abraded by hand tools in workshop. All surfaces were throughly cleaned. Belzona 2911 Primer has been applied as thin coat. Then the leaking area of Air Cooler Cover filled and coated with Belzona 2211 MP Hi-Build Elastomer to provide seal air and seawater.
Belzona Facts
Air Cooler did not allow the gasket under the cover to be changed due to its design. This made the missing seal difficult to repair. Belzona was the only alternative that could seal from the outside to withstand vibrations.