BELZONA SEALS CHEMICAL BUNKERS FROM THE ENVIRONMENT

KHIA ID: 1187
Industry: General Industry (GIND)
Application: RPA-Roof Problem Areas (RPA)
Substrate: concrete
Customer Location: Fertilizer Plant, North Alabama USA
Application Date: 1999
Products: Belzona® 3111 (Flexible Membrane)

Problem: Water was penetrating into the expansion joints and cracks, reacting with old fertilizer which could cause further concrete failure and chemical release into the environment.
Photograph Descriptions
  1. Cleaning the concrete
  2. Overall view of cracks conditioned with Belzona® 3911
  3. Joints and cracks sealed with Belzona® 3111
  4. Spraying coat of clear cladding
Application Situation
Underground fertilizer storage bunker
Application Method
Application was carried out in accordance with a modified Belzona Know-How System Leaflet RPA-1. Surface prepared by pressure washing then all cracks and joints sealed with Belzona® 3111 system. A coat of clear cladding was applied over the entire concrete storage area.
Belzona Facts
Caulks and RTV had failed over the years due to UV degradation. Belzona® 3111 has lasted 10 years with minor repairs due to structural movement.