KHIA ID: 7543Industry: Chemical & Petrochemical (PETR)
Application: GSS-Gaskets, Seals and Shims (GSS)
Substrate: Carbon Steel and ConcreteCustomer Location: Petrochemical Plant, UK
Application Date: 2013Products:Belzona 3131 (WG Membrane)
Belzona 6111 (Liquid Anode)
Belzona 1121 (Super XL Metal)
Problem: This hydrogen flare stack had recently been installed on site, but gaps around the “hold down bolts” had resulted in water ingress to the underside of the stack. Several solutions were considered, but with 28 bolts and fins to accommodate, the obvious choice was a Belzona Tank Base Seal solution.
1. Initial condition for Flare Stack
2. Close-up of hold down bolt gaps
3. Gaps filled and surfaces primed
4. Tank Base Seal completed in 2013