Belzona Protects Incinerator Exhaust Duct

KHIA ID: 7560
Industry: Food & Drink (FOOD)
Application: VPF-Valves, Pipes and Fittings (VPF)
Substrate: 316 Stainless steel
Customer Location: Food Producing Company, Eastern Norway
Application Date: November 2016
Products:

Belzona 1591 (Ceramic XHT)


Problem: The vapor from the burning waste was damaging all earlier attempted coating systems. The Customer needed a heavy duty coating, tolerant of operation in wet conditions up to 160°C.
Photograph Descriptions

1. Units overview.

2. Gritblasting details and application preparation.

3. Coating application details.

4. Completed application ready for transport.

Application Situation
Internal surfaces of incenerator exhaust duct used to dispose of waste from local food factory.
Application Method
Application was carried out in accordance with Belzona System Leaflet VPF-2. Following gritblasting all internal surfaces of the 2 chimney units were coated with Belzona 1591.
Belzona Facts
The customer replied back after 6 months that the application was so far working perfectly and initiated several more similiar applications in the future.