Belzona Strengthens Nozzles of High-pressure Flare Scrubber on Offshore Platform

KHIA ID: 8570
Industry: Oil & Gas (OILG)
Application: VPF-Valves, Pipes and Fittings (VPF)
Substrate: Carbon Steel
Customer Location: China
Application Date: 2017
Products:

Belzona 1511 (Super HT- Metal)

Belzona 1983 (Belzona Superwrap II Resin)

Belzona 9381

Belzona 9382

Belzona 9111.


Problem: Due to the damage of the original insulation layer, the nozzle of the high-pressure flare scrubber was corroded under the insulation layer (CUI). The thickness of the nozzle was seriously reduced.
Photograph Descriptions

1. Nozzles with serious corrosion problems

2. Surface preparation with water blasting

3. Complete application of Belzona Superwrap II

Application Situation
Nozzles of high-pressure flare scrubbers on offshore platform suffering from corrosion and significant thickness loss. The design pressure is 1.035MPa, the design temperature is -48℃∽100℃.
Application Method
The repairs were designed in accordance with ISO24817 standard. The application was completed by Belzona trained and validated installers in accordance with Belzona Know-How System Leaflet VPF-11. Belzona supervisor and the on-site representative  supervised the whole process. The whole application included 2 one and half-inch nozzles, 10 two-inch nozzles, 4 three-inch nozzles and 1 four-inch nozzle.
Belzona Facts
For conventional welding, the whole high-pressure flare scrubber need to be shut down and isolated, with thorough cleaning and water injection, which costs at least 15 days of downtime and affects the production. Welding in confined space may also cause hazards. Therefore, the customer has been looking for the solutions with no hot work required but also accepted by classification society. Meeting the standard of ISO24817and ASME PCC-2, Belzona Superwrap II can repair the nozzles of pressure vessels on-site, with no downtime or hot work required. The application is still in good condition after 3 years.