Belzona Superwrap 2 system repairs storage tank

KHIA ID: 8945
Industry: Chemical & Petrochemical (PETR)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Carbon steel
Customer Location: Scotland
Application Date: January 2023
Products: Belzona 1111 (Super Metal),Belzona 1981 (SuperWrap II)

Problem: A leak had developed in a storage tank due to corrosion.

Leaking area

Belzona 1111 & Superwrap 2 applied

Completed application

Application Situation
No hot works were possible in the area due to the tank's location. A cold applied repair was required to repair this leak long term.
Application Method
The area was prepared with an MBX Bristle Blaster to SSPC SP11. A cold plate bond was then applied using Belzona 1111. This plate was then encapsulated with Belzona Superwrap 2
Belzona Facts
This repair was carried out in 1.5 days, allowing a fast return to service for the customer