Belzona provides Leading Edge Protection (LEP)

KHIA ID: 8583
Industry: Power (POWR)
Application: FBC-Fans, Blowers and Compressors (FBC)
Substrate: Composite fibre
Customer Location: Doncaster
Application Date: September 2021
Products:

Belzona 5811 (immersion grade)

Belzona 5721


Problem: A cooling tower with 4 x 9mø cells, each with 9 x 4.5m blades was to be refurbished, the main part of the works was to replace the blades. This was mainly due to wear and expected erosion leading to failure of the blades Our client stepped in to offer a solution to keep the existing blades and coat them to protect the client's assets
Photograph Descriptions

1. Training taking place

2. Blades awaiting preparation

3. Finished blades awaiting dispatch to site

4. Closer detail of finished LEP and full body protection coating

Application Situation
36 x 4.5m x 750mm blades were to be protected using Belzona's recently released protection coating, specifically designed for Leading Edge Protection. 
Application Method
Training was given from the UK Sales Technical team to the contractors at their works The blades were sanded to provide a key then 2 x coats of 5811 were applied to the total surfaces of the fan blades. After curing, the 5811 was again abraded along on the leading edge, appx 80mm either side of the blade's leading edge to the length of the blade. 2 coats of 5721 was then applied to complete the protective application
Belzona Facts
The cost to replace the blades could have been between 5 and 25 times that of the cost of the Belzona materials used. This application has also paved the way for the Contractor to offer the same service on many other sites.