Belzona renovate a process tank

KHIA ID: 8169
Industry: Food & Drink (FOOD)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Steel
Customer Location: France
Application Date: January 2020
Products:

Belzona 5892


Problem: The internal lining of the tank was corroded due to the products being acidic when they are at high temperatures.
Photograph Descriptions

1 - Tank after grit blasting  2 - During application of Belzona 5892  3 - Tank after complete coating

Application Situation
Internal lining of a wheat starch milk tank in a factory
Application Method
Application was carried out in accordance with Belzona System Leaflet TCC-5. The tank was previously grit blasted to remove the rust before applying 2 coats of Belzona 5892. Small retouches were made before the coating system was post-cured with steam.
Belzona Facts
The remplacement of the tank would have cost ‎€1,000,000 whereas the Belzona repair was 10 times less (€100,000). The customer was quick to chose Belzona as the previous competitor coatings have failed.