DEIONIZER COATED WITH BELZONA

KHIA ID: 618
Industry: Water / Wastewater (WATR)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Carbon steel
Customer Location: Medicine factory in Egypt
Application Date: August 2004
Products:

Belzona® 5811 (Immersion Grade)


Problem: Failure of rubber lining due to aging and chemical attack.
Photograph Descriptions
  1. General view of the deionizer
  2. The failed rubber lining
  3. Deionizer from inside after coating
  4. Application completed
Application Situation
Deionizer in the companys water treatment plant.
Application Method
Application was carried out in accordance with Belzona Know-How System Leaflet TCC-5.
Belzona Facts
Rubber lining was removed then Belzona® 5811 was applied to provide long term protection to the deionizer. The deionizer was inspected after a year and found to be in perfect condition. More deionizers were then coated.