Keeping the rain out with Belzona Expansion Joints

KHIA ID: 512
Industry: Buildings & Structures (BSTR)
Application: FPA-Floor Problem Areas (FPA)
Substrate: Asphalt and brick
Customer Location: Local Authority, St.Helens, UK
Application Date: June 2004
Products:

Belzona® 4521 (Magma-Flex Fluid)

Belzona® 2211 (MP Hi-Build)

Belzona® 4111 (Magma-Quartz)


Problem: Leaking expansion joints
Photograph Descriptions
  1. Old joint being scraped out 
  2. Joints masked off ready for re-filling 
  3. The completed repair 
  4. An external 7-meter vertical expansion joint
Application Situation
Vertical and horizontal expansion joints in asphalt floor and brick walls of shelterd housing complex.
Application Method
The application was carried out in accordance with Belzona Know-How System Leaflets FPA-5 & FPA-6.
Belzona Facts
The old expansion joints were not flexible enough and were allowing rainwater to seep through into the neighboring dwellings causing damp problems. The joints were removed and filled using Belzona® 4521 for the horizontal joints and Belzona® 2211 for the vertical. A layer of Belzona® 2211 was also applied over the horizontal joints to improve the aesthetics of the repair.