Pump Bowels Coated with Belzona 1391T
Industry: Oil & Gas (OILG)
Application: CEP-Centrifugal Pumps (CEP)
Substrate: NAB Nickel Aluminum Bronze
Customer Location: Eastern Province Saudi Arabia
Application Date: January 2025
Products: Belzona 1391T
Problem: The customer was looking for a protective system against the effect of corrosion and erosion at high temperatures for the pump bowels.
Pump bowel after blasting
First coat of Belzona 1391T
Second coat of Belzona 1391T on the pump dicsharge head
Complete application on Pump bowel
Application Situation
The customer required solution that can protect the equipment for years to come against the corrosion and erosion effects over high temperatures up to 100 °C.
Application Method
1. Grit Blasting was done to achieve a near-white metal surface and a minimum 75 µm profile.
2. As per Belzona IFU, we applied a 2-coat system of Belzona 1391T, each of 450 µm thickness to reach a total DFT of 800-900 µm.
Belzona Facts
Belzona has proven records in Aramco and approved in one of the standards; it was chosen to protect the pump due to its long history and proven durability, ease of application and long term protections.