Turbine Restored and Protected with Belzona
Industry: Mining & Quarrying (MINQ)
Application: FBC-Fans, Blowers and Compressors (FBC)
Substrate: Steel
Customer Location: Portugal
Application Date: 2015
Products:
Belzona 1311 (Bearing Metal)
Belzona 1331
Problem: General erosion-corrosion on the turbine of a blower used as part of copper mining process. The erosion had caused a loss of material which could result in balancing issues.
Photograph Descriptions
1. Overview of the blower
2. Eroded-corrode turbine
3. Belzona 1331 being applied to the turbine
4. blower back in service
Application Situation
Repair of a turbine suffering from corrosion and erosion.
Application Method
Application carried out in accordance with Belzona Know-How System leaflet FBC-01 & FBC-02. The turbine was grit blasted down to SA 2.5 and then the lost structure was rebuilt with Belzona 1311. Finally 2 coats of Belzona 1331 was applied to prevent further corrosion-erosion.
Belzona Facts
The cold applied Belzona solution was a fraction of the cost of having to replace the whole turbine and offered a quick return to service for the customer.