Wind Turbine LEP repaired with Belzona 5721

KHIA ID: 8584
Industry: Power (POWR)
Application: FBC-Fans, Blowers and Compressors (FBC)
Substrate: GRP
Customer Location: Poland
Application Date: July 2021
Products:

Belzona 1221 (Super E-Metal)

Belzona 5721


Problem: A large energy company in Poland were looking for a solution to repair pitting of the LEP of a wind turbine blades and also supply a LEP coating over the repaired areas.
Photograph Descriptions
  1. LEP Surface Preparation Image 
  2. Application of Belzona 1221 pit filling 
  3. Application of Belzona 5721 for the LEP 
  4. Completed Application
Application Situation
Belzona 5721 LEP Coating was applied by rope access at a large wind turbine park in Poland.
Application Method
The Wind Turbine LEP was repaired in line with Belzona System Leaflet FBC-16.
Belzona Facts
An easy In-Situ application applied by rope access to ensure minimal downtime for the wind turbine. Belzona products are able to repair both pitting and the apply a protective LEP coating for the long term protection of the leading edge.