Application Situation:

Auxiliary cooling water pump

 
 

Problem:

Severe abrasion damage to cutwater area of the pump meant loss of efficiency.

 
 

Products:

Belzona® 1311 (Ceramic R Metal)

Belzona® 1321 (Ceramic S Metal)

 

Substrate:

Cast steel

 
 

Application Method:

Application was carried out in accordance with modified versions of Belzona Know-How system leaflets CEP-1 & -3. An anchor point was drilled and fixed through the casing. Belzona® 1311 was used to restore the required profile using timber formers to gain required shape. Belzona® 1321 applied to give area erosion corrosion protection.

 
 

Belzona Facts:

This pump had lasted only two years before these repairs were required. The repaired pump has been in service since 2007 and is still running with no additional repairs required.

 
 