BELZONA REPAIRS ACW PUMP
Industry: Power (POWR)
Application: CEP-Centrifugal Pumps (CEP)
Substrate: Cast steel
Customer Location: Nuclear Power Station, UK
Application Date: September 2007
Products:
Belzona® 1311 (Ceramic R Metal)
Belzona® 1321 (Ceramic S Metal)
Problem: Severe abrasion damage to cutwater area of the pump meant loss of efficiency.
Photograph Descriptions
- Damaged area with anchor pin in place
- Former in position
- Damaged area rebuilt with Belzona® 1311
- Finished job after application of Belzona® 1321
Application Situation
Auxiliary cooling water pump
Application Method
Application was carried out in accordance with modified versions of Belzona Know-How system leaflets CEP-1 & -3. An anchor point was drilled and fixed through the casing. Belzona® 1311 was used to restore the required profile using timber formers to gain required shape. Belzona® 1321 applied to give area erosion corrosion protection.
Belzona Facts
This pump had lasted only two years before these repairs were required. The repaired pump has been in service since 2007 and is still running with no additional repairs required.