BELZONA PROTECTION TO AERZENER LOBE COMPRESSOR

KHIA ID: 365
Industry: General Industry (GIND)
Application: PDP-Positive Displacement Pumps (PDP)
Substrate: Steel
Customer Location: Steel Mill in Saudi Arabia
Application Date: 2002
Products:

Belzona® 1111 (Super Metal)

Belzona® 1391


Problem: Hot scrubbed gas contains fine particles which are broken down by spraying with water, this combination causes severe corrosion.
Photograph Descriptions
  1. General view of compressor
  2. Work underway on the lobe
  3. Body and lobe protected with Belzona® 1391
Application Situation
Compressors used to boost process and cool gases in the steel production process.
Application Method
Application was carried out using a modified version of Belzona System Leaflets PDP-4, FBC-2 and FBC-5. Pitting damage repaired with Belzona® 1111 and internal casing and lobe protected with Belzona® 1391.
Belzona Facts
Initial compressor completed as a trial. As a result of this successful trial further units have since been coated.