BELZONA PROTECTS COAL DIRECTOR

KHIA ID: 461
Industry: Power (POWR)
Application: SHM-Solids Handling Machinery (SHM)
Substrate: Carbon Steel
Customer Location: Coal-fired Power Plant - Ontario, Canada
Application Date: June 2004
Products:

Belzona® 1812 (Ceramic Carbide FP)


Problem: The steel plate on the coal director was worn through and in need of replacement.
Photograph Descriptions
  1. Surface preparation
  2. Product was kept warm with the help of this steam pipe
  3. Completed application
Application Situation
Coal director for pulverizer
Application Method
Application was carried out in accordance with Belzona Know-How System Leaflet SHM-13.
Belzona Facts
New steel was put in place. Steel was hand prepared and Belzona® 1812 material was put down with 1/8" thickness. This Belzona system provides excellent abrasion resistance, while ensuring the coal moves as required.