BELZONA PROTECTS HAZARDS DRAIN TANK

KHIA ID: 6337
Промышленность: Oil & Gas (OILG)
Заявление: TCC-Tanks and Chemical Containment Areas (TCC)
Субстрат: Carbon Steel
Местоположение клиента: Offshore platform, UK North Sea
Дата подачи документов: August 2016
Продукты:

Belzona 1391S

Belzona 1391T 


Проблема: Once opened and inspected it was decided to replace the lower 1 meter of the existing coating before putting the tank back into service. MIC (microbiologically induced corrosion) was affecting the bottom of the tank and causing local pitting of the steel.
Описание фотографий

1. Original coating 2. Grit blasting underway 3. Inspection of 1st Coat 4. Completed application with 2nd coat applied.

Ситуация с приложением
A hazards drains tank found to be suffering metal loss when UT inspected.
Способ применения
Application was carried out in accordance with Belzona System Leaflets TCC-3 and TCC-5. after rebuilding deep pits with Belzona paste grade rebuilding product, Belzona 1391S was applied using heated airless spray with Belzona 1391T applied by brush as a stripe coat.
Белзона Факты
Belzona was specified due to its successful track record on similar equipment and its user friendly application characteristics.