BELZONA PROTECTS IRRIGATION CULVERT
Industry: Water / Wastewater (WATR)
Application: VPF-Valves, Pipes and Fittings (VPF)
Substrate: Galvanized steel
Customer Location: Irrigation District - Wyoming, USA
Application Date: March 2007
Products: Belzona® 5811 (Immersion Grade)
Belzona® 9331 (Reinforcing sheet)
Problem: Debris, sand, and silt carried by irrigation water wore through the galvanizing in one season. Left uncorrected, the underlying carbon steel pipe would quickly corrode leading to soil erosion.
Photograph Descriptions
- The galvanized culvert to be protected
- Belzona® 5811 being applied via airless spray
- The completed application
- Inspected after one season of operation
Application Situation
Galvanized steel pipe used to carry 400 ft³/s of irrigation water.
Application Method
Belzona® 5811 and Belzona® 9331 were applied in accordance with a modified Belzona Know-How System Leaflet VPF-2.
Belzona Facts
Replacement of the damaged pipe would have cost $700,000 and taken considerable time to complete. The Belzona repair was conducted quickly in situ and saved the customer $650,000.
Inspected after one season and found to be in excellent condition.