BELZONA PROTECTS VERTICAL FLARE KNOCK OUT VESSEL

KHIA ID: 488
Industry: Chemical & Petrochemical (PETR)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Steel
Customer Location: Oil Refinery-Australia
Application Date: May 2004
Products:

Belzona® 5891 (HT Immersion Grade)


Problem: Internal corrosion caused by variety of hydrocarbons and chemicals passing through the vessel.
Photograph Descriptions
  1. General view of the vessel
  2. The degree of existing corrosion found in the vessel 
  3. Application of Belzona® 5891 underway
Application Situation
Vertical Flare knock-out vessel. This is second stage of the flare stack line and is half filled with water to form a seal for dissolved Hydrocarbons, H2S but mainly sour water.
Application Method
Application was carried out in accordance with Belzona Know-How System Leaflet TCC-5. After thorough cleaning, the vessel was grit blasted and coated with the Belzona® 5891.
Belzona Facts
Belzona® 5891 provides excellent protection to a wide range of Hydrocarbons and other chemicals at the elevated temperatures anticipated in this vessel.