BELZONA RECONSTRUCTS THE COVER AND FLANGE OF A HEAT EXCHANGER

KHIA ID: 7972
Industry: ()
Application: HEX-Heat Exchangers (HEX)
Substrate: Carbon steel
Customer Location: Petrochemical Plant, Gabon
Application Date: April 2019
Products:

Belzona 1111 (Super-Metal)


Problem: The flange and the cover of this exchanger were badly damaged by corrosion and needed to be rebuilt.
Photograph Descriptions

1- Cover before application

2- Flange before application

3- Flange after application

4- Cover after application

Application Situation
Cover and flange of a heat exchanger
Application Method
The substrate was first grit blasted to ensure a good mechanical bond with the product. Belzona 1111 was then used to rebuild the cover and the flange according to a modified version of Belzona System Leaflet HEX-02. Finally, the 2 parts of this equipment were machined back to the correct dimensions.
Belzona Facts
The customer needed a cold applied solution as no hot work was authorised on this equipment.