BELZONA REPAIRS LEAKING TRANSFORMER FINS

KHIA ID: 1492
Industry: Power (POWR)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Steel
Customer Location: Wind Farm, UK
Application Date: 2007
Products:

Belzona® 1161 (Super UW Metal)


Problem: Lower edge of fins corroded and starting to leak. Problem caused by sheep rubbing against fins, damaging paint system.
Photograph Descriptions
  1. Previous temporary repair
  2. Surface preparation
  3. Bonding with Belzona® 1161
  4. Completed application
Application Situation
Fins on oil filled transformer
Application Method
Application was carried out in accordance with Belzona Know-How System Leaflet TCC-1. Pre-formed doubler plates were bonded over the corroded areas after manual surface preparation. 
Belzona Facts
Client had tried unsuccessfully to seal leaks before turning to Belzona. The Belzona® 1161 provides an effective bond in oil contaminated areas and use of doubler plates ensures repair will remain effective for many years.