BELZONA REPAIRS PROFILE OF HYDROELECTRIC DAM

KHIA ID: 5285
Industry: Power (POWR)
Application: FPA-Floor Problem Areas (FPA)
Substrate: Concrete and exposed reinforcing bar
Customer Location: Washington, USA
Application Date: October 2012
Products:

Belzona 4111 (Magma-Quartz)


Problem: The profile of a small hydroelectric dam became worn, exposing reinforcing bar, which was caused by damage from VW sized boulders tumbling into and over the face of dam during spring runoff. The client was concerned about maintaining the integrity of the small hydroelectric dam and restoring the original profile.
Photograph Descriptions
  1. Dam (ogee) profile before repairs
  2. Several pallets of Belzona 4111 on site
  3. Dam repairs underway - note templates & mixer
  4. Completed application
Application Situation
Rebuilding the profile of a small hydroelectric dam.  
Application Method
With the help of plywood templates, the dam profile was rebuilt with Belzona 4111 applied by hand. The application time was limited due to possible mountain runoff. Work was tightly monitored and contained so as not to pollute nearby fish spawning grounds.
Belzona Facts
The client was previously familiar with the bond strength and mechanical properties of Belzona 4111. Several other comparable materials had been considered.