Belzona Repairs and Protects a Corroded Feeding Pipe
Industry: Chemical & Petrochemical (PETR)
Application: VPF-Valves, Pipes and Fittings (VPF)
Substrate: Carbon steel
Customer Location: Petrochemical Plant, France
Application Date: November 2018
Products:
Belzona 1212
Belzona 4341 (Magma CR4)
Problem: The pipe was perforated due to corrosion and sulphuric acid was leaking out.
Photograph Descriptions
Before application.
After Belzona 1212 to plug the leak.
Belzona 4341 applied with reinforcement sheets.
Final application.
Application Situation
Emergency repair on a feeding pipe circulating sulphuric acid into a storage tank.
Application Method
The leak was plugged with Belzona 1212 in order to secure the pipe. The surface was then manually prepared and Belzona 4341 was used with a reinforcement sheet all around the pipe to reinforce its structure and protect it against acid, in accordance with Belzona system leaflet VPF-11.
Belzona Facts
The distributor was on site for another application but the customer needed this pipe to be urgently repaired. The customer chose Belzona for its speed, the ease of application and the good chemical resistance of the system.