Belzona repairs pump caissons
Industry: Oil & Gas (OILG)
Application: VPF-Valves, Pipes and Fittings (VPF)
Substrate: Steel
Customer Location: Azerbaijan - Offshore
Application Date: August 2018
Products:
Belzona 1212
Belzona 1161 (UW-Metal)
Belzona 5831 (ST)
Belzona 9341 (Reinforcement Sheet)
Problem: Through wall defects of pipe causing leakage of water with large areas of pitting.
Photograph Descriptions
- Defective pipe
- Doubler plate
- Belzona 5831 1st coat
- Belzona 5831 2nd coat
Application Situation
Pump caisson pipe suffering from external corrosion and through-wall defects
Application Method
The application was completed in accordance with Belzona System leaflet VPF-11 and SOS-21. Through wall defects were repaired by plate bonding using Belzona 1212. Pitting was repaired with Belzona 1161 followed by 2 coats of Belzona 5831 with Reinforcement Sheet between the coats.
Belzona Facts
Client required 10 year life expectancy for the repair.