END COVER OF CONDENSER RECEIVES BELZONA HT SOLUTION

KHIA ID: 5806
Industry: Oil & Gas (OILG)
Application: HEX-Heat Exchangers (HEX)
Substrate: Carbon Steel
Customer Location: Gas Plant, Southeast China
Application Date: August 2010
Products:

Belzona 1511 (Super HT-Metal)

Belzona 1591 (Ceramic XHT)


Problem: Severe pitting corrosion appeared on the cover after years of operation. The worst pitting is about 10mm deep.
Photograph Descriptions
  1. The internal surface before application
  2. Severe pitting damage
  3. Completed application
  4. The coating after 4 years shows no sign of further corrosion
Application Situation
End cover of condenser. Design temperature: 130°C; design pressure 0.1MPa
Application Method
Application was carried out in accordance with Belzona Know-How System Leaflet HEX-3. Belzona 1511 was used to rebuild the profile followed by an application of Belzona 1591 as a high temperature protective coating.
Belzona Facts
The cover was originally unlined. Belzona's solution prevented the cover from further corrosion, extended the equipment life and eliminated the cost of replacement. After 4 years in service, the coating is in perfect condition.