Leaking Porous Weld Repair

KHIA ID: 9352
Industry: Water / Wastewater (WATR)
Application: VPF-Valves, Pipes and Fittings (VPF)
Substrate: Stainless-steel
Customer Location: Ontario
Application Date: November 2023
Products: Belzona 1111 (Super Metal),Belzona 9111 (Cleaner Degreaser)

Problem: Weld Joint on stainless steel pipe was leaking due to a porosity and slag inclusion

Repair area preparation completed

Belzona 1111 mixed

Application of Belzona 1111

Application completed

Application Situation
The asset owner required a weld joint on the city water tower S/S filling pipe to be repaired without performing hot work and also required a NSF approved product.
Application Method
Preparation was completed in-way of using a grinder with a 80 grit sanding pad, than cleaned with Belzona 9111. Next the Belzona 1111 repair composite was mixed and applied well into the preferred area. Using a piece of Belzona 9341 Reinforcing cloth was wetted out and applied over the repair area with a further layer of Belzona 1111 until the cloth was covered.
Belzona Facts
Sub-Contractor contacted Belzona Great Lakes to discuss solutions the BGL would suggest to be used for this type of repair and also mentioned that a approved NSF-61 product was required.