RESTORATION OF BRONZE IMPELLER WITH BELZONA

KHIA ID: 724
Industry: Water / Wastewater (WATR)
Application: CEP-Centrifugal Pumps (CEP)
Substrate: Bronze
Customer Location: AEP/PSO - Oolagah, OK
Application Date: June, 2005
Products:

Belzona® 1311 (Ceramic-R Metal)

Belzona® 1321 (Ceramic-S Metal)


Problem: This pump impeller, 1 of 4, normally running 24/7 had eroded to the point of replacement.
Photograph Descriptions
  1. First inspection showing extent of erosion damage
  2. Mesh in place and rebuild proceeding
  3. Grinding to contour
  4. Rebuilt and ready for service
Application Situation
Cooling water pump impeller.
Application Method
Application was carried out in accordance with Belzona Know-How System Leaflet CEP-1, CEP-3 and CEP-5. Stainless Steel mesh used to reform vanes. After rebuilding, grinding to original profiles and coating, impeller was re-balanced.
Belzona Facts
Downtime was critical in this application and although replacement could be flown in within 6 days, further machining would be required. Belzona application was completed within 3 days.