RESTORING AND COATING E5B HEAT EXCHANGER FACE
Industry: Steel & Metal Processing (STEL)
Application: HEX-Heat Exchangers (HEX)
Substrate: Carbon steel
Customer Location: Brazil
Application Date: July 2011
Products: Belzona 1111 (Super Metal), Belzona 1321 (Ceramic S-Metal)
Problem: Galvanic corrosion on the tube face, caused by contact of 2 dissimilar metals.
3.) Applying Belzona 1111 for the rebuild
4.) Final application - removal of corks
Application Situation
Rebuilding and coating a heat exchanger in situ, the heat exchanger is used to transfer heat used in the steel manufacturing process.
Application Method
The application was carried out in accordance with system leaflet HEX-01.
The application area was marked out before the tube face was grit blasted to SA2.5, achieving a minimum 75-micron profile. After blasting, the tube face was rebuilt with Belzona 1111, followed by 2 coats of Belzona 1321, each coat was applied at 250-375 microns. After the Belzona had cured, a visual inspection was carried out and any areas requiring touch-ups were marked up, abraded, and then re-coated.
Before the HEX was put back in service, the equipment passed a hydrostatic test carried out by the client under a pressure of 30 kg/cm².
Belzona Facts
The client was satisfied with the solution as the application was carried out in situ and avoided the need to dissemble the HEX.