BELZONA EXCELS WHERE OTHERS FAIL!

KHIA ID: 375
Industry: General Industry (GIND)
Application: MPT-Mechanical Power Transmission (MPT)
Substrate: Steel
Customer Location: Metal Forging Company - in the Northeast - U.S.A.
Application Date: February 2003
Products:

Belzona® 1111 (Super Metal)

Belzona® 9111 (Cleaner/Degreaser)


Problem: Forging machine cam failed, imitator product failed in one week.
Photograph Descriptions
  1. The Cam
  2. Products being used
  3. The completed application
Application Situation
Forging Machine Cam
Application Method
The application was carried out in accordance with a modified version of Belzona Know-How Systems Leaflet MPT-12. Damaged areas were ground down. Following degreasing, Belzona® 1111 was applied, then ground/sanded back to profile.
Belzona Facts
Application saved tens of thousands of dollars in downtime, as disassembly of machine takes four days. Four months in service - PERFECT!