BELZONA PROTECTS OF 10 '' AND 3 '' VALVES ON THE COAST
Industry: Oil & Gas (OILG)
Application: GSS-Gaskets, Seals and Shims (GSS)
Substrate: Steel
Customer Location: Petroleum Terminal, Gabon
Application Date: March 2017
Problem: Corrosion problem on 10" valve bolts and several 3" flanges.
Photograph Descriptions
1. Surface preparation 2. Application of the first beige layer of Belzona 3411 in progress 3. Application of the second grey layer of Belzona 3411 4. Application of the Belzona 3411 on the 3" flanges
Application Situation
Valves and flanges on the coast exposed in a corrosive environment.
Application Method
Application was carried out in accordance with Belzona System Leaflet GSS-11. The Belzona protection system was applied by brush without the installation of plastic caps. This does not affect the corrosion resistance of the system.
Belzona Facts
The cold-applied, Belzona system has been chosen in preference to a thermoplastic, hot-applied protection system. The corrosion protection offered by the Belzona 8411/3411 system is ideally suited to encapsulating equipment located in this coastal environment.