BELZONA SEALS HIGH RISE ROOF

KHIA ID: 6187
Industry: Buildings & Structures (BSTR)
Application: RPA-Roof Problem Areas (RPA)
Substrate: Concrete
Customer Location: Commercial property, Brisbane, Queensland, Australia
Application Date: September 2012
Products:

Belzona 4151 (Magma Quartz Resins)

Belzona 3111 (Flexible Membrane)


Problem: Water was leaking into the offices below and required a waterproof solution.
Photograph Descriptions

1. The roof prior to application 2.  The finished coating 3. Alternate view of the sealed area

Application Situation
Concrete deck around cooling tower on the roof of a high rise building.
Application Method
The application was carried out in accordance with Belzona System Leaflet RPA-1. he concrete was power washed to remove all dirt and detritus. Cracks that were revealed following the cleaning were then filled and sealed using Belzona 4151. The entire roof area was then coated with a fully reinforced Belzona 3111 system.
Belzona Facts
Belzona products and systems were chosen for there solvent free properties that prevented odours being drawn into the building and for there long term protective properties.