BELZONA SEALS UPPER FLOOR PUMP ROOM

KHIA ID: 1145
Industry: Buildings & Structures (BSTR)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Concrete
Customer Location: County Hospital, Colton California U.S.A.
Application Date: 2007
Products: Belzona® 5811 (Immersion Grade)

Problem: Copper pipes leaking water on the floor was leaking through the concrete to the lower level.
Photograph Descriptions
  1. The pump room showing the pipes that keep leaking
  2. Reinforcement tape used for edges
  3. Back of pump room
  4. Finished floor
Application Situation
Pump room at hospital positioned on floor above computer room.
Application Method
Application was carried out using a modified Belzona Know-How System TCC-15.
After washing and removing dirt from floor Belzona® 5811 was used to coat the entire floor plus 6 inches up the wall to completely encapsulate the area and to form a containment area.
Belzona Facts
This application saved the hospital tens of thousands of dollars due to the last time the floor leaked it ruined all of the PCs below.