BIG SAVINGS WITH BELZONA’s UNCONVENTIONAL REPAIR TECHNIQUES

KHIA ID: 372
Industry: Chemical & Petrochemical (PETR)
Application: GSS-Gaskets, Seals and Shims (GSS)
Substrate: Steel & Concrete
Customer Location: Petrochemical facility - Minnesota,U.S.A.
Application Date: June 2001
Products:

Belzona® 4151 (Magma-Quartz Resins)


Problem: Hollow spots under pump base between the grout and the steel base created vibration, thereby causing pre-mature bearing failure.
Photograph Descriptions
  1. Removal of pump from base
  2. Installing injection ports
  3. Injecting with gun
Application Situation
Bearing failure in pump from vibration.
Application Method
The Application was carried out in accordance with a modified version of Belzona Know-How Systems leaflet GSS-9. Injection Method: Product placed in pneumatic gun, injected using static mixer.
Belzona Facts
This can be completed for 1/10th the cost of rebuilding and regrouting the pump base. Application is so successful, over 200 pump bases have been done at this facility.