KHIA ID: 10006Industry: Oil & Gas (OILG)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Carbon steelCustomer Location: ABU DHABI, UNITED ARAB EMIRATES
Application Date: August 2025Products: Belzona 1391T
Problem: One of our offshore clients experienced significant internal deterioration of their 3-phase test separator due to erosion-corrosion. The equipment operates at 121°C and processes sour hydrocarbons, which contributed to the accelerated degradation. This condition severely compromised the integrity and performance of the unit, raising serious concerns about operational reliability and safety. A comprehensive technical assessment was carried out, and appropriate mitigation measures were implemented to prevent further damage and restore the system’s functionality.
The Test separator suffered severe erosion-corrosion, compromising equipment integrity and safety.
Surface preparation was carried out via grit blasting to SA 2.5 standard.
The damaged areas were then treated with a first coat of Belzona 1391T.
A second coat of Belzona 1391T was applied to ensure durable, long-term protection.