BELZONA PROTECTS DESALTER FROM CORROSION

KHIA ID: 7758
Industria: Oil & Gas (OILG)
Solicitud: TCC-Tanks and Chemical Containment Areas (TCC)
Sustrato: Mild steel
Ubicación del cliente: Scotland
Fecha de aplicacion: May 2018
Productos:

Belzona 1511 (HT metal)

Belzona 1523

Belzona 1593


Fecha de aplicacion: The vessels contained hydrocarbons, salts & wet H2S at high temperature. The previous coating had failed, leaving the vessel exposed to the potential for corrosion.
Descripciones de fotografías

Osmotic blistering in existing coating

Surface after grit blasting

Belzona 1511 used to pit fill

Two coats of Belzona 1523 applied by spray

Situación de la aplicación
Two desalters had come out of service. Osmotic blistering had been noted on the previous coating within the vessel. A long term solution was required to protect the two vessels from corrosion.
Método de aplicación
The vessels were blasted to SA2.5 & minimum 75 microns using garnet. Salt tests were carried out to ensure the levels were within acceptable limits. Any pits found were filled with Belzona 1511. Hard to spray areas were stripe coated with Belzona 1593. Two coats of Belzona 1523 were then applied. The application was carried out in accordance with Belzona System Leaflet TCC-5.
Datos de Belzona
The vessel coating was completed within a tight shutdown window. This method of coating rather than replacing the vessels ensured long term protection with minimal disruption to the plant.