External Rebuilding and Protection with Belzona

KHIA ID: 9155
Industry: Chemical & Petrochemical (PETR)
Application: VPF-Valves, Pipes and Fittings (VPF)
Substrate: Carbon steel
Customer Location: Cartagena/ Colombia
Application Date: October 2016
Products: Belzona 1161 (Super UW-Metal)

Problem: Severe corrosion on the outside of the 6" inch pipe, pitting is evident.

Pitting on pipe

First layer of Belzona 1161 and reinforcement mesh.

Work completed.

Application Situation
Replacement would be at least 10 times more expensive than rebuilding with Belzona.
Application Method
The surface of the tube was prepared with a steel brush and sandpaper.
Initially the product was impregnated with a short bristle brush on the substrate, then with the applicator was given the desired thickness and a good finish.
Belzona Facts
By rebuilding the surface with Belzona 1161, we stop the corrosion, recovered the surface and avoid the replacement of the valve section.