KHIA ID: 9329Industry: Power (POWR)
Application: GSS-Gaskets, Seals and Shims (GSS)
Substrate: Carbon steelCustomer Location: Ireland
Application Date: March 2023Products: Belzona 3412, Belzona 8411
Problem: The area around the top flange of the transformer was corroding. The corrosion was also effecting the bolts. The flange area has been recoated with paint on three occasions, however this had not produced a satisfactory solution. There was a gap between the flanges of approximately 10mm. This gap was up to 100mm deep. There was potential movement between the flanges due to thermal expansion or other factors.
When the paint was applied, the gap between the flanges was filled with a filler material to provide a surface for the paint to go over in this area.
If a solid filler was used, it would crack with movement between the flanges, leading to a crack in the paint and subsequent failure. If a flexible filler was used, the epoxy paint would crack if there was movement between the flanges also leading to failure of the paint.
Main Station transformer
Typical corrosion at the main flange
Close up of Belzona 3412 seal on the flange
Belzona 3412